Skip to main content
Clean Hydrogen Partnership

Explosion in a trays cleaning unit

Event

Event ID
312
Quality
Description

A wash machine was being used to clean aluminium trays with burnt on product. The auto wash in normal situations cleaned steel trays, and not aluminium. The cleaning fluid contained sodium hydroxide (NaOH). When it entered in contact with the cleaning fluid a "froth" formed in the wash tub, accompanied with hydrogen gas.

A cleaning worker was requested to clean up the froth, and used a wet vacuum cleaner. This cleaner seemingly also removed the hydrogen element with the froth, which in turn ignited due to sparking from the vacuum cleaner motor.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Europe
Country
United Kingdom
Date
Component involved
vacuum cleaner
Failure mode
internal explosion
Initiating cause
run-away reaction
Root CAUSE analysis

The INITIATING CAUSE was the accidental formation of hydrogen when washing aluminium tray with sodium hydroxide.

There was a lack of understanding of the cleaning product used and its applications, as COSHH sheets on this product, available on site, explicitly stated that this product was not to be used on aluminium.

The ROOT CAUSE is failure to understand and apply procedures.

Root causes
Date entry in HIAD
28/02/2009

Facility

Application
Other
Sub-application
Industrial cleaner
Hydrogen supply chain stage
All components affected

Industrial vacuum cleaner

Location type
Unknown
Location
industrial area
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
1
Post-event summary

The cleaner was uninjured but took time off due to shock, which resulted in the incident being reported.

Emergency action

No emergency action was stated in the report

Lesson Learnt

Lesson Learnt

This incident is an example of a low-technology industrial process where things went wrong when something was changed to the process. The process had been designed for washing used for steel parts. When washing aluminium parts, the cleaning fluid behaved differently. In absence of an extensive knowledge of the ongoing chemical process, operators try usually to remediate to the unexpected results with what is available onsite.

However, to avoid the incident would have been enough to read the safety sheets held by the company, which specifically stated not to use on Aluminium. There was a lack of understanding and availability of this information on behalf of manager.
Nevertheless, the investigation conclusions were that

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE
Explosion type

References

Sources categories
HSE
Reference & weblink

Event description provided by HSE, original source confidential