Fire from falling cylinders

Event

Event ID
297
Quality
Description

A vehicle (non-further specified) carrying two hydrogen gas cylinders had to brake suddenly. The two cylinders tipped over, damaging the valve and causing hydrogen gas to leak out and ignite.
The vehicle was completely burned, no one was injured. The cylinders had fallen over because not secured.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
fire
Macro-region
Asia
Country
Japan
Date
Component involved
valve (generic)
Failure mode
rupture & ignition
Initiating cause
impact, rollover, crash
Root CAUSE analysis

The INITIATING was a road event (sudden braking)
The ROOT CAUSE was not having secured the cylinders to the vehicle structure, to avoid they could fly around.

Root causes
Date entry in HIAD
30/08/2025

Facility

Application
Hydrogen transport and distribution
Sub-application
CGH2 cylinders truck
Hydrogen supply chain stage
All components affected

cylinder valves

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Open
Location
unknown
Operational condition

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release temperature [°C]
25
Probable IGNITION SOURCE

References

Sources categories
KHK
Reference & weblink

High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association):
https://www.khk.or.jp/public_information/incident_investigation/hpg_inc…