Skip to main content
Clean Hydrogen Partnership

Leak from a CGH2 tube trailer

Event

Event ID
290
Quality
Description

A tube trailer carrying compressed hydrogen was travelling on a highway, when the drivers heard suddenly heard the sound of leaking gas. They stopped and discovered that that gas was escaping from the fusible plug of one of the cartridges, so traffic was restricted.
The KHK report does not provide information on if and how the leak was stopped, and on the reasons for the failure. Information on how the emergency was handled is also missing.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
Asia
Country
Japan
Date
Component involved
TPRD (burst disc)
Failure mode
premature activation & venting
Initiating cause
unknown
Root CAUSE analysis

The INITIATING CAUSE was the opening of the thermally-activated pressure relief device (TPRD), expected to activate in case of temperature increases.
Nothing is known on the reason. Since no pressure anomaly was reported, it is plausible to assume that the TPRD failed pre-maturely due to material defect. The KHK report attributed the ROOT CAUSE to “inspection failure”, without however explaining why the inspection failed.

Root causes
Date entry in HIAD
30/08/2025

Facility

Application
Hydrogen transport and distribution
Sub-application
CGH2 tube trailer
Hydrogen supply chain stage
All components affected

fusible plug, TPRD

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Open
Location
highway or similar
Operational condition
Pre-event occurrences

There were 22 long tubes on the trailer

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Post-event summary

The only information availabe is that "traffic was restricted".

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Release temperature [°C]
25
Probable IGNITION SOURCE

References

Sources categories
KHK
Reference & weblink

High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association):
https://www.khk.or.jp/public_information/incident_investigation/hpg_inc…
(accessed May 2025)