Event
- Event ID
- 224
- Quality
- Description
A compressed hydrogen tube trailer was fully loaded and parked, when a rupture disc on one of the tubes failed. The escaping hydrogen ignited.
9583 cu ft (approximately 23 kg) of hydrogen were released.- Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- fire
- Macro-region
- North America
- Country
- United States
- Date
- Component involved
- PRD (burst disc)
- Failure mode
- premature activation & venting
- Initiating cause
- material degradation (generic)
- Root CAUSE analysis
The INITIATING CAUSE was the premature opening of the burst disc.
The ROOT CAUSE is unknown, because it is unknown if the disc failed due to lack of maintenance, wrong installation or wrong material choice.- Root causes
- Date entry in HIAD
- 20/01/2025
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- CGH2 tube trailer
- Hydrogen supply chain stage
- All components affected
burst disc
- Process temperature range [C]
- ambient temperature (-50°C to +50°C)
- Process pressure range [MPa]
- medium to high pressure (10 to 50 MPa)
- Location type
- Open
- Location
- industrial area
- Operational condition
- Pre-event occurrences
Assuming that the trailer was consisting of 10 tubes, the total transported quantity was approximately 230 kg.
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 0
- Currency
- US$
- Property loss (onsite)
- 0
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount (kg)
- 22.75406686
- Release temperature [°C]
- 25
- Probable IGNITION SOURCE
References
- Sources categories
- Zalosh
- Reference & weblink
Extract from Table III of Appendix A of Zalosh and Short
COMPARATIVE ANALYSIS OF HYDROGEN FIRE AND EXPLOSION INCIDENTS
Quarterly Report No. 2 for Period December 1, 1977 - February 28, 1978
https://www.osti.gov/biblio/6566131
(accessed September 2020)