Fire from a CGH2 tube trailer just loaded

Event

Event ID
224
Quality
Description

A compressed hydrogen tube trailer was fully loaded and parked, when a rupture disc on one of the tubes failed. The escaping hydrogen ignited.
9583 cu ft (approximately 23 kg) of hydrogen were released.

Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
fire
Macro-region
North America
Country
United States
Date
Component involved
PRD (burst disc)
Failure mode
premature activation & venting
Initiating cause
material degradation (generic)
Root CAUSE analysis

The INITIATING CAUSE was the premature opening of the burst disc.
The ROOT CAUSE is unknown, because it is unknown if the disc failed due to lack of maintenance, wrong installation or wrong material choice.

Root causes
Date entry in HIAD
20/01/2025

Facility

Application
Hydrogen transport and distribution
Sub-application
CGH2 tube trailer
Hydrogen supply chain stage
All components affected

burst disc

Process temperature range [C]
ambient temperature (-50°C to +50°C)
Process pressure range [MPa]
medium to high pressure (10 to 50 MPa)
Location type
Open
Location
industrial area
Operational condition
Pre-event occurrences

Assuming that the trailer was consisting of 10 tubes, the total transported quantity was approximately 230 kg.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
0

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Released amount (kg)
22.75406686
Release temperature [°C]
25
Probable IGNITION SOURCE

References

Sources categories
Zalosh
Reference & weblink

Extract from Table III of Appendix A of Zalosh and Short
COMPARATIVE ANALYSIS OF HYDROGEN FIRE AND EXPLOSION INCIDENTS
Quarterly Report No. 2 for Period December 1, 1977 - February 28, 1978
https://www.osti.gov/biblio/6566131
(accessed September 2020)