A truck loaded with 400 hydrogen bottles crashed into a concrete barrier and tipped over. After tipping over, the vehicle slid about 150 meters across the road. The hydrogen was released, ignited producing an explosion and eventually involving the tractor in the fire.
Around 50 firefighters were busy extinguishing the fire for two hours. To reduce the risk of explosion, the fire brigade cooled the gas bottles with extinguishing water at the scene of the fire. The motorway was closed for around eight hours.The driver's cab burned out completely in the accident. The damage to the vehicle to 200,000 euros, without counting the damage to the highway surface
- Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- Macro-region
- Europe
- Country
- Germany
- Date
- Component involved
- valve (generic)
- Failure mode
- rupture & ignition
- Initiating cause
- impact, rollover, crash
- Root CAUSE analysis
The INITIATING CAUSE was the crash of the vehicle against a concrete barrier.
- Root causes
- Date entry in HIAD
- 08/12/2024
Facility
- Application
- Hydrogen transport and distribution
- Sub-application
- CGH2 cylinders truck
- Hydrogen supply chain stage
- All components affected
cylinders
- Process temperature range [C]
- ambient temperature (-50°C to +50°C)
- Process pressure range [MPa]
- medium to high pressure (10 to 50 MPa)
- Location type
- Open
- Location
- highway or similar
- Operational condition
- Pre-event occurrences
The trailer was transporting 400 bottles. The report mention 200 -l bottles. By looking at the picture, the bottles appear standard 50 litre, 200 bar bottles. Assuming they were all full, it give a total hydrogen inventory of approximately 290 kg.
Emergency & Consequences
- Number of fatalities
- 0
- Number of injured persons
- 1
- Currency
- Euro
- Property loss (onsite)
- 200.000
- Post-event summary
The driver's cab burned out completely in the accident. The damage to the vehicle to 200,000 euros, without counting the damage to the highway surface
- Emergency action
The fire the highway triggered a major fire service emergency operation. Around 50 firefighters were busy extinguishing the fire for two hours. To reduce the risk of explosion, the fire brigade cooled the gas bottles with extinguishing water at the scene of the fire. As there was not enough water at the scene of the accident, water hoses were laid over several hundred meters.
The motorway was closed for around eight hours.
In-depth data
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount (kg)
- 290
- Release temperature [°C]
- 25
- Release pressure [MPa]
- 20
- Probable IGNITION SOURCE
- Explosion type
References
- Sources categories
- News
- Reference & weblink
Online news WELT
https://www.welt.de/regionales/nrw/article842473/Gastransporter-explodi…