Skip to main content
Clean Hydrogen Partnership

Small release from a LH2 tanker due to road vibration

Event

Event ID
77
Quality
Description

A liquid hydrogen tanker was driving on a highway, when the driver noticed a vapour plume in his mirror. Driver stopped and found a small amount of vapour coming from the vapour recovery line, which was slightly open. The driver closed the valve tightly and the vapour plume ceased.
The valve had opened slightly due road vibration. Since the check at company repair facility did not reveal any problem, the tanker was put back in services.

Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
leak no ignition
Macro-region
North America
Country
United States
Date
Component involved
flange (bolts)
Failure mode
rupture, no ignition
Initiating cause
loss of tightness (road vibrations)
Root CAUSE analysis

INITIAL CAUSE was the opening the vapour recovery valve due to vibration.
The ROOT CAUSE was a design which did not took into account the whole range of mechanical solicitations which the pressure control system of the trailer could experiment when travelling.

Root causes
Date entry in HIAD
31/12/2024

Facility

Application
Hydrogen transport and distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
All components affected

vapour recovery valve

Process temperature range [C]
cryogenic temperature (below -50°C)
Process pressure range [MPa]
low to medium pressure (below 2 MPa)
Location type
Open
Location
highway or similar
Operational condition
Pre-event occurrences

It is unknown if the tanker was full or empty.
The capacity is given in GCF (2005.2 GCF) , which possibly does not refer to the max load of a LH2 tanker, but to the hydrogen gas left in the tank before venting.

Emergency & Consequences

Number of fatalities
0
Number of injured persons
0
Currency
US$
Property loss (onsite)
1
Post-event summary

A loss of 100 GCF is reported, which probably corresponds to 0.3 kg

Emergency action

The driver closed tighter the valve.

Lesson Learnt

Lesson Learnt

This incident is very similar to other, such as the HIAD_070, which attributed to road vibrations the opening of the vapour return valve.

In-depth data

Release type
gas
Involved substances (% vol)
H2 100%
Probable IGNITION SOURCE

References

Sources categories
PHMSA
Reference & weblink

Event incident ID I-1991090457 of the PHMSA database (Pipeline and Hazardous Materials Safety Administration, 1996),
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages
(accessed September 2024)